In large-scale buildings—whether industrial plants, commercial offices, or cultural centers—fire-rated assemblies are critical to protecting occupants, infrastructure, and assets. These assemblies integrate multiple building components, including ceilings, walls, and structural frameworks, all designed to resist fire for a specified period.
A vital but sometimes underestimated part of these assemblies is the ceiling T bar system. By supporting suspended ceiling panels, providing structural stability, and accommodating acoustic infill or fire-resistant panels, aluminium and steel ceiling T bars contribute directly to the fire safety rating of the assembly. With fire resistance ranging from 60 to 120 minutes, T bar systems help delay the spread of flames and smoke, giving occupants more time to evacuate.
This article explores the role of ceiling T bars in fire-rated assemblies, covering technical specifications, global standards, supplier solutions, and case studies from industrial and commercial projects.
Fire-rated assemblies are required under codes like ASTM E119 and EN 13501, ensuring structures withstand fire for specific timeframes.
Delaying fire spread allows safe evacuation and provides critical time for fire services.
Industrial plants, data centers, and cultural centers contain high-value equipment and artifacts. Fire-rated assemblies minimize losses.
T bars form the grid that suspends ceiling panels. Their metal composition—aluminium or steel—resists warping and sagging under high temperatures.
Fire-rated acoustic panels require structural backing. T bars ensure NRC ≥0.75 is maintained even under thermal stress.
|
Material |
NRC |
Fire Resistance |
STC |
Service Life |
|
Aluminium |
0.78–0.82 |
60–90 min |
≥40 |
25–30 yrs |
|
Steel |
0.75–0.80 |
90–120 min |
≥38 |
20–25 yrs |
|
Gypsum Grids |
≤0.55 |
30–60 min |
≤30 |
10–12 yrs |
|
Wood Grids |
≤0.50 |
Combustible |
≤25 |
7–12 yrs |
|
PVC Grids |
≤0.50 |
Poor |
≤20 |
7–10 yrs |
|
System |
NRC After Install |
NRC After 10 Years |
Fire Resistance |
Service Life |
|
Aluminium T Bar |
0.82 |
0.79 |
60–90 min |
25–30 yrs |
|
Steel T Bar |
0.80 |
0.77 |
90–120 min |
20–25 yrs |
|
Gypsum Grids |
0.52 |
0.45 |
30–60 min |
10–12 yrs |
PRANCE supplies aluminium and steel T bar ceiling systems engineered for fire-rated assemblies. With NRC ≥0.75, STC ≥40, and fire resistance of 60–120 minutes, PRANCE solutions are applied in industrial plants, clean rooms, and cultural centers worldwide. Get in touch with PRANCE today to explore our aluminium and steel T bar systems for your industrial or commercial project.
They provide the structural grid that supports fire-resistant panels, delaying collapse under heat.
Steel offers up to 120 minutes, while aluminium provides up to 90 minutes.
Yes, NRC ≥0.75 can be maintained with acoustic infill.
Yes, but steel is preferred for extended fire durations.
No. They fail to meet durability and fire resistance standards.