PRANCE metalwork is a leading manufacturer of metal ceiling and facade systems.
An open cell ceiling uses intersecting blades to form a regular grid, leaving the ceiling void partly visible through its openings. Cell size determines the scale of the grid pattern, while blade depth affects how much of the overhead services can be screened from different viewing angles. A 100 × 100 mm grid with 50 mm blades may look balanced on plan but still leave cable trays visible from the entrance.
This guide compares 75, 100, and 150 mm open cell ceiling sizes with 50 and 60 mm blade depths, explains how to evaluate screening from different viewing positions, and covers mockup checks and the dimensions to record on ceiling drawings.
On an open grid ceiling, closer blade spacing creates a denser pattern, while wider spacing makes the individual openings more noticeable. Across a 600 mm span, center-to-center pitches of 75, 100, and 150 mm produce eight, six, and four grid intervals respectively. The difference is visible in the number of blade lines across the same area. Confirm the clear opening separately if a light or other component needs to fit between the blades.
Keep the blade face width and depth the same when comparing these three cell sizes:
| Cell Size | Grid Apperance | Ceiling Void Visibility |
| 75 × 75 mm | Fine, dense pattern with closely spaced blades | Smaller openings can limit views into the ceiling void from oblique angles. |
| 100 × 100 mm | Moderate grid density with more defined openings | Offers an intermediate level of openness and overhead visibility. |
| 150 × 150 mm | More open pattern with larger, pronounced openings | Wider openings can expose more of the ceiling void and overhead services. |
Lay out each candidate open cell ceiling across the same ceiling bay on the plan. If a wider pitch leaves awkward cuts at a prominent edge, test a different grid starting point before changing the cell size.
For a 100 × 100 mm open cell ceiling, 50 mm blades are a starting point if they screen the overhead services adequately from the main viewing positions. If the cable tray remains prominent from the entrance, compare a 60 mm blade with the same face width. The taller side face can intercept more of an angled view into the ceiling void, or plenum, while making the grid appear more enclosed. Blade depth is the vertical dimension of the profile; the plan spacing stays the same.
Ask the supplier to confirm that both depths are available. Compare the 50 mm and 60 mm samples at the same finished ceiling height and under the same lighting. Check both the visibility of the tray and the shadows on the blade side faces. Retain 50 mm if it provides sufficient screening, or select 60 mm if the additional depth improves concealment without making the grid look too enclosed.
An open cell ceiling can screen a tray from the doorway while leaving it visible to someone standing directly below. From the doorway, the line of sight crosses the sides of the blades. From below, it can pass almost straight through a cell. Compare the open cell grid ceiling from both positions at the intended finished ceiling height. Include a representative section of tray so the team can judge what the grid screens under the proposed conditions. If the open cell ceiling continues over a reception desk, include the seated view. A person at the desk may see a different part of the plenum than someone entering the office.
If the grid spacing looks right but the cable tray remains visible, compare a deeper blade before changing the cell size. If the pattern looks too sparse, test a smaller cell at the original blade depth. Where the grid works from the entrance but leaves services exposed directly below, check whether the tray can be relocated.
For the office entrance example, assemble a section of the open cell ceiling using the 100 × 100 mm grid and 50 mm blades, with a representative cable tray above it at the proposed location. Compare changes to the grid or blade profiles under representative lighting, keeping the tray location and viewing positions fixed. Change one dimension at a time to identify its effect.
|
What you see in the mockup
|
What to change first | Where to check again |
| The grid spacing looks right, but the tray draws attention at the entrance | Keep the cell size and compare a deeper blade | Stand at the same spot in the doorway |
| The pattern looks too sparse along the main route | Try a smaller cell at the original blade depth | Walk the same route and review the pattern and tray visibility |
| The entrance view works, but the tray is visible directly above a spot that requires screening | Ask the building services team if the tray can move out of that sightline | Check both the position below the tray and the doorway |
If the deeper blade improves the entrance view but makes the grid look too enclosed, review the tray layout before approving the depth.
In the Australia Lobby Open Cell Ceiling Project, PRANCE's 200 × 200 mm aluminum open-cell grid was used across the ceiling and walls. Before surface finishing, PRANCE carried out a trial assembly for the client to review grid spacing and joint gaps. This allowed the assembled grid appearance to be checked against the design requirements before delivery.
The final open cell ceiling configuration needs to meet both the intended grid appearance and the screening requirements at the specified viewing positions. Take photos from the same marked positions for comparison, then record the agreed cell size, blade depth, and reasons for the selection.
On the reflected ceiling plan or in the associated schedule, identify the open cell ceiling by zone and record the agreed cell size and blade depth. State whether the cell dimension is the clear opening or the center-to-center pitch. Check the proposed light positions against the grid lines. If tray relocation is part of the approved solution, record it on the coordinated services drawings so the ceiling quote and shop drawings reflect the same design.
A larger cell size creates a more open grid pattern but can leave more overhead services visible. Deeper blades improve screening from angled views without changing the grid spacing, though they can make the ceiling appear more enclosed. The final open cell ceiling specification selection needs to balance these effects at the intended viewing positions. If a cable tray remains visible directly below, relocating it may be more effective than changing the ceiling grid.
Send PRANCE your ceiling plan, finished ceiling height, and the locations of the services you want to screen. These details help define which size combinations to compare and what to carry into the shop drawings.
No single standard cell size applies to all open cell ceiling systems. Common options include 75 × 75 mm, 100 × 100 mm, and 150 × 150 mm, depending on the product series. Suppliers may define cell size by center-to-center pitch or clear opening, so confirm the measurement on a dimensioned product drawing before comparing quotes.
No. Blade depth is the vertical height of the blade profile, while ceiling drop is the distance from a specified overhead reference to the finished ceiling plane. The total space required also depends on the suspension, carriers, and building services. Check the section drawing when the available ceiling void is limited.
No. An open cell ceiling can partially screen overhead services, but visibility depends on cell size, blade depth, and viewing angle. Equipment may remain visible directly through the grid. If complete concealment is required, a closed ceiling zone may be necessary.
*We will reply within 24 hours. If you don't receive our email, please check your spam folder. For urgent inquiries, please reach out via WhatsApp: +86-13809708787
* Kindly ensure your email and phone number are correct so our specialist can reach you promptly, or you can send a message to our whatsapp +86-13809708787